Goldi Solar / fleet monitor
daily report
Fleet/Reports/2026-09-06
Daily report

Sunday, 06 September 2026

Generated
47,712 kWh
To grid
47,116 kWh
Revenue (generated)
₹190,848
Revenue (billable)
₹188,465
CO₂ avoided
33.9 t
Inverters active
34/75
Data completeness
79.4%

Plants

Billable shown in copper where the meter recorded under 85% of generation — meter fault or curtailment.

PlantActiveGeneratedTo grid PeakYield kWh/kWpPR₹ gen₹ billable
Helium5,700 kWp est 14/14 20,068 kWh 19,666 2,517 kW 3.52 0.584 ₹80,272 ₹78,665
White Lotus2,910 kWp est 8/8 12,031 kWh 11,954 2,072 kW 4.13 — ₹48,123 ₹47,816
Jamnadas3,430 kWp est 8/8 9,886 kWh 9,810 1,968 kW 2.88 — ₹39,545 ₹39,240
Madhav1,460 kWp est 4/4 5,727 kWh 5,686 1,011 kW 3.92 0.752 ₹22,908 ₹22,744
Aamantran1,090 kWp est 0/3 — kWh no meter — kW — — ₹0 —
Arogya1,120 kWp est 0/3 — kWh no meter — kW — — ₹0 —
Kanhaiya1,080 kWp est 0/3 — kWh no meter — kW — — ₹0 —
Kiran5,100 kWp est 0/14 — kWh no meter — kW — — ₹0 —
Murliwala1,080 kWp est 0/3 — kWh no meter — kW — — ₹0 —
Ravani1,090 kWp est 0/3 — kWh no meter — kW — — ₹0 —
Roopwada4,370 kWp est 0/12 — kWh no meter — kW — — ₹0 —

Events

Opened on this day, plus anything still open. Dead strings: Jamnadas_INV01 (5), Jamnadas_INV02 (2), Jamnadas_INV04 (5), Jamnadas_INV05 (3), Jamnadas_INV07 (4).

SeverityTypeMessageStatus
CRITICAL DEVICE_OFFLINERoopwada_INV09 silent for 558.2 h CLEARED
CRITICAL DEVICE_OFFLINERoopwada_INV07 silent for 558.2 h CLEARED
CRITICAL DEVICE_OFFLINERoopwada_INV06 silent for 558.2 h CLEARED
CRITICAL DEVICE_OFFLINERoopwada_INV05 silent for 558.2 h CLEARED
CRITICAL DEVICE_OFFLINERoopwada_INV04 silent for 558.2 h CLEARED
CRITICAL DEVICE_OFFLINERoopwada_INV03 silent for 558.2 h CLEARED
CRITICAL DEVICE_OFFLINERoopwada_INV02 silent for 558.2 h CLEARED
CRITICAL DEVICE_OFFLINERoopwada_INV01 silent for 558.2 h CLEARED
CRITICAL DEVICE_OFFLINEMurliwala_MFM01 silent for 101.6 h CLEARED
CRITICAL DEVICE_OFFLINEMurliwala_INV01 silent for 101.4 h CLEARED
CRITICAL DEVICE_OFFLINEArogya_MFM01 silent for 100.4 h CLEARED
CRITICAL DEVICE_OFFLINEArogya_INV01 silent for 100.5 h CLEARED
CRITICAL DEVICE_OFFLINERoopwada_INV08 silent for 558.2 h CLEARED
CRITICAL DEVICE_OFFLINERoopwada_INV10 silent for 558.2 h CLEARED
CRITICAL DEVICE_OFFLINERoopwada_INV11 silent for 558.2 h CLEARED
CRITICAL DEVICE_OFFLINERoopwada_INV12 silent for 558.2 h CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV09 reporting but generating 0 kW while fleet produces 3447 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV12 reporting but generating 0 kW while fleet produces 3447 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV02 reporting but generating 0 kW while fleet produces 3447 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV01 reporting but generating 0 kW while fleet produces 3447 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV05 reporting but generating 0 kW while fleet produces 3447 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV04 reporting but generating 0 kW while fleet produces 3447 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV07 reporting but generating 0 kW while fleet produces 3447 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV06 reporting but generating 0 kW while fleet produces 3447 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV10 reporting but generating 0 kW while fleet produces 3447 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV14 reporting but generating 0 kW while fleet produces 3447 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV03 reporting but generating 0 kW while fleet produces 3447 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV11 reporting but generating 0 kW while fleet produces 3447 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV08 reporting but generating 0 kW while fleet produces 3447 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV13 reporting but generating 0 kW while fleet produces 3447 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV02 reporting but generating 0 kW while fleet produces 4546 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV05 reporting but generating 0 kW while fleet produces 4546 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV06 reporting but generating 0 kW while fleet produces 4546 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV03 reporting but generating 0 kW while fleet produces 4546 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV14 reporting but generating 0 kW while fleet produces 4546 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV01 reporting but generating 0 kW while fleet produces 4546 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV04 reporting but generating 0 kW while fleet produces 4546 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV11 reporting but generating 0 kW while fleet produces 4546 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV09 reporting but generating 0 kW while fleet produces 4546 kW CLEARED
WARNING ZERO_GENERATION_DAYTIMEHelium_INV08 reporting but generating 0 kW while fleet produces 4546 kW CLEARED