Billable shown in copper where the meter recorded under 85% of generation — meter fault or curtailment.
| Plant | Active | Generated | To grid | Peak | Yield kWh/kWp | PR | ₹ gen | ₹ billable |
|---|---|---|---|---|---|---|---|---|
| Helium5,700 kWp est | 14/14 | 25,243 kWh | 24,734 | 2,620 kW | 4.43 | 0.660 | ₹100,972 | ₹98,937 |
| White Lotus2,910 kWp est | 8/8 | 14,006 kWh | 13,912 | 2,119 kW | 4.81 | — | ₹56,025 | ₹55,650 |
| Jamnadas3,430 kWp est | 8/8 | 13,997 kWh | 13,890 | 2,017 kW | 4.08 | — | ₹55,988 | ₹55,560 |
| Madhav1,460 kWp est | 4/4 | 6,446 kWh | 6,403 | 966 kW | 4.42 | 0.742 | ₹25,786 | ₹25,612 |
| Aamantran1,090 kWp est | 0/3 | — kWh | no meter | — kW | — | — | ₹0 | — |
| Arogya1,120 kWp est | 0/3 | — kWh | no meter | — kW | — | — | ₹0 | — |
| Kanhaiya1,080 kWp est | 0/3 | — kWh | no meter | — kW | — | — | ₹0 | — |
| Kiran5,100 kWp est | 0/14 | — kWh | no meter | — kW | — | — | ₹0 | — |
| Murliwala1,080 kWp est | 0/3 | — kWh | no meter | — kW | — | — | ₹0 | — |
| Ravani1,090 kWp est | 0/3 | — kWh | no meter | — kW | — | — | ₹0 | — |
| Roopwada4,370 kWp est | 0/12 | — kWh | no meter | — kW | — | — | ₹0 | — |
Opened on this day, plus anything still open. Dead strings: Jamnadas_INV01 (5), Jamnadas_INV02 (2), Jamnadas_INV04 (5), Jamnadas_INV05 (3), Jamnadas_INV07 (4).
| Severity | Type | Message | Status |
|---|---|---|---|
| CRITICAL | DEVICE_OFFLINE | Roopwada_INV07 silent for 678.2 h | CLEARED |
| CRITICAL | DEVICE_OFFLINE | Roopwada_INV04 silent for 678.2 h | CLEARED |
| CRITICAL | DEVICE_OFFLINE | Roopwada_INV03 silent for 678.2 h | CLEARED |
| CRITICAL | DEVICE_OFFLINE | Roopwada_INV02 silent for 678.2 h | CLEARED |
| CRITICAL | DEVICE_OFFLINE | Roopwada_INV01 silent for 678.2 h | CLEARED |
| CRITICAL | DEVICE_OFFLINE | Murliwala_MFM01 silent for 221.6 h | CLEARED |
| CRITICAL | DEVICE_OFFLINE | Murliwala_INV01 silent for 221.4 h | CLEARED |
| CRITICAL | DEVICE_OFFLINE | Arogya_MFM01 silent for 220.4 h | CLEARED |
| CRITICAL | DEVICE_OFFLINE | Arogya_INV01 silent for 220.5 h | CLEARED |
| CRITICAL | DEVICE_OFFLINE | Roopwada_INV05 silent for 678.2 h | CLEARED |
| CRITICAL | DEVICE_OFFLINE | Roopwada_INV06 silent for 678.2 h | CLEARED |
| CRITICAL | DEVICE_OFFLINE | Roopwada_INV08 silent for 678.2 h | CLEARED |
| CRITICAL | DEVICE_OFFLINE | Roopwada_INV09 silent for 678.2 h | CLEARED |
| CRITICAL | DEVICE_OFFLINE | Roopwada_INV10 silent for 678.2 h | CLEARED |
| CRITICAL | DEVICE_OFFLINE | Roopwada_INV11 silent for 678.2 h | CLEARED |
| CRITICAL | DEVICE_OFFLINE | Roopwada_INV12 silent for 678.2 h | CLEARED |
| WARNING | DEVICE_OFFLINE | Madhav_WMS1 silent for 55 min | CLEARED |
| WARNING | DEVICE_OFFLINE | WHITE_LOTUS_INV04 silent for 55 min | CLEARED |
| WARNING | DEVICE_OFFLINE | WHITE_LOTUS_INV05 silent for 55 min | CLEARED |
| WARNING | DEVICE_OFFLINE | WHITE_LOTUS_INV07 silent for 55 min | CLEARED |
| WARNING | DEVICE_OFFLINE | WHITE_LOTUS_MFM01 silent for 55 min | CLEARED |
| WARNING | DEVICE_OFFLINE | WHITE_LOTUS_INV08 silent for 55 min | CLEARED |
| WARNING | DEVICE_OFFLINE | Madhav_INV01 silent for 60 min | CLEARED |
| WARNING | DEVICE_OFFLINE | Madhav_MFM01 silent for 55 min | CLEARED |
| WARNING | DEVICE_OFFLINE | WHITE_LOTUS_INV02 silent for 55 min | CLEARED |
| WARNING | DEVICE_OFFLINE | WHITE_LOTUS_INV01 silent for 55 min | CLEARED |
| WARNING | DEVICE_OFFLINE | WHITE_LOTUS_INV03 silent for 55 min | CLEARED |
| WARNING | DEVICE_OFFLINE | Madhav_INV03 silent for 60 min | CLEARED |
| WARNING | DEVICE_OFFLINE | WHITE_LOTUS_INV06 silent for 55 min | CLEARED |
| WARNING | DEVICE_OFFLINE | Madhav_INV02 silent for 60 min | CLEARED |
| WARNING | DEVICE_OFFLINE | Madhav_INV04 silent for 60 min | CLEARED |
| WARNING | ZERO_GENERATION_DAYTIME | Helium_INV14 reporting but generating 0 kW while fleet produces 5304 kW | CLEARED |
| WARNING | ZERO_GENERATION_DAYTIME | Helium_INV12 reporting but generating 0 kW while fleet produces 5304 kW | CLEARED |
| WARNING | ZERO_GENERATION_DAYTIME | Helium_INV11 reporting but generating 0 kW while fleet produces 5304 kW | CLEARED |
| WARNING | ZERO_GENERATION_DAYTIME | Helium_INV04 reporting but generating 0 kW while fleet produces 5304 kW | CLEARED |
| WARNING | ZERO_GENERATION_DAYTIME | Helium_INV05 reporting but generating 0 kW while fleet produces 5304 kW | CLEARED |
| WARNING | ZERO_GENERATION_DAYTIME | Helium_INV06 reporting but generating 0 kW while fleet produces 5304 kW | CLEARED |
| WARNING | ZERO_GENERATION_DAYTIME | Helium_INV07 reporting but generating 0 kW while fleet produces 5304 kW | CLEARED |
| WARNING | ZERO_GENERATION_DAYTIME | Helium_INV08 reporting but generating 0 kW while fleet produces 5304 kW | CLEARED |
| WARNING | ZERO_GENERATION_DAYTIME | Helium_INV09 reporting but generating 0 kW while fleet produces 5304 kW | CLEARED |